The amperometric analyzer is epa approved for online residual. Dulcometer products encompass a complete range of quality instrumentation from single channel transmitters to multichannel disinfection controllers. Prominent dosiertechnik gmbh d69123 heidelberg germany. The cl10 sc reagentless chlorine analyzer allows for realtime control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed. Free chlorine analyzer fc80 electrochemical devices. Electrical and plumbing diagrams wdmpsc, cl10sc and cl17 doc273. Free chlorine analysis system epa compliant free chlorine measurement using amperometric sensor technology eliminates reagents.
The measuring result of type cle free chlorine is subtracted from the. Prominent dulcometer d1cbd1cc controller by prominent gmbh. Ozone, without cross sensitivity to chlorine, hydrogen peroxide. English us, french, spanish, portuguese, chinese, japanese, korean. The ecd tc80 total chlorine analyzer is a panel mounted, ready to use total chlorine analyzer. The system consists of the sensors, an analyzer either 56 series analyzers controllers or 1056 dual input analyzer and constant head overflow cup to control sample flow. Prominent dulcometer d1c operating instructions manual pdf. Please carefully read these operating instructions before use. Dulcometer d1cb d1cc assembly and operating instructions. Hach has a complete portfolio of instruments and chemistries with support and services to help you get the right results. The d1cb d1cc controller is a 1channel p pid controller controls processes automatically to ensure that the specified values e.
These systems incorporate a memosens amperometric free chlorine probe and a memosens ph probe for accurate. Instruction manual chlorine residual analyzer, series 1770. Indoor, as close as possible to the sample point to reduce sampling dead time. This video demonstrates sensor removal, filling the membrane cap, and basic programming of the d1ca.
Features the model 87625 total free chlorine and ph analyzer has the following features. Prominent dosiertechnik gmbh 69123 heidelberg germany. The controllers dulcometer d1cb and dulcometer d1cc differ from each other only in their type of housing and mounting loca. This method allows the use of any type of on line chlorine analyzer e. The cl10 sc analyzer uses hach s exclusive cal watch self. The controller dulcometer d1cbd1cc can be used for control tasks in. A chlorine and ph calibration kit are supplied with the unit. The compact measuring and control system for the reliable monitoring and treatment of potable and similar types of water. Chlorine dioxide system for the metering of chlorine dioxide with concentrated starting chemicals. Available in either 90260 vac or 1224 vdc power supply systems. Measuring instruments prominent dulcometer d1c operating instructions manual part 3. Hca1 chlorine plus photometer system instruction manual ideal for the measurement of free and total chlorine in drinking water, waste water, environmental or other clear water samples.
With prominent s product catalogue you have all information at a glance. By continuing to browse the site you are agreeing to our use of cookies. Dulcometer d1cb d1cc prominent fluid controls, inc. For operation on controllers with 420 ma input measured variable. Prominent d1cb and d1cc analyzers temperature data panel mount permissible ambient temperature basic version. This symbol is used to designate a warning risk of electrical shock. Most recent version of the cl17 chlorine analyzer user manual in all available languages product information choose the version and language of the cl17 chlorine analyzer user manual. It is designed to monitor total chlorine in drinking water, industrial cooling and rinse water, wastewater or other fresh water samples containing chlorine in the range of 020 ppm. R module control module for chlorine gas metering units. The ecd fc80 free chlorine analyzer is a panel mounted, ready to use free chlorine analyzer. It is primarily intended to be used by drinking water utilities for compliance with daily monitoring requirements. The proven threestage safety concept protects people and the environment.
Dulcometer prominent manual pdf download pdf manual free. Free download of the current version of the wikasofttt software at. Our products optimize your process reliability and increase plant efficiency. These general operating instructions facilitate the installation and calibration of the. Prominent d2c manual prominent fluid controls australia manuals prominent dulcometer analyzers provide precise monitoring or controlling of process dulcometer dmt 2tr dstransmitter prominent dulcometer transmitters type dmt are compact 2wiretransmitters for the measuring variable ph, redox, chlorine, conductive conductivity and temperature. Rosemount analytical fcl free chlorine measuring system. The rc400g residual chlorine analyzer employs a polarographic system that uses rotating platinum electrodes to provide continuous online measurement of residual chlorine concentration.
This symbol is used to designate important information, warnings and cautions. Clf10 sc and clt10 sc dimensional drawing pdf document. End user channel partner kuntze usa is committed to protecting and respecting your privacy, and well only use your personal information to administer your account and to provide the products and services you requested from us. Safe, convenient and clear, thanks to the large illuminated graphic display, plain text operating menu and ph sensor monitoring. Controller prominent dulcometer d1cb assembly and operating instructions manual 155 pages. Hca1 chlorine plus photometer system instruction manual. Newly developed pumps, standardized metering systems, unique uv plants. It is designed to monitor free chlorine residual chlorine in drinking water, industrial cooling and rinse water, wastewater or other fresh water samples containing chlorine in the range of 0. Dulcometer d1c and dulcotest cle chlorine sensor for free. Products chlorine sensor prominent fluid controls, inc. Many water suppliers use chlorine for disinfection. A measurement range from 020 ppm ensures process control in a wide range of disinfection applications.
Atis chlorine monitor is an upgraded version of our proven q45h system for continuous water quality monitoring of free or combined chlorine. Using an online chlorine analyzer this method is for the analysis of residual chlorine free or total in drinking water. Increasingly stringent environmental requirements and greater need for process optimization and safety are upping the demand for consistently precise chlorine feed and dosage control. Cl17 free and total chlorine analyzer calibrationverification instruction sheet 5449089.
Monitor capabilities have been expanded to include options for a 3rd analog output or for adding additional low power relay outputs. About this document this manual contains instructions for installation and operation of the model tcl total chlorine analyzer. Proper installation, operation and servicing of this device in a hazardous area instal lation is entirely the responsibility of the user. Adjustment and operation, measured variable chlorite. A tailormade metering system is the perfect alternative when a complete overhaul is economically not feasible. Clf10 sc and clt10 sc csi specifications pdf document.
Diaphragmcovered measuring electrodes ensure reliable operation and long service life even under. Please completely read through operating instructions. Enhanced measuring and process safety as housing is resistant to electrical interference due to a potential equalizer pin. Analog outputs are additionally completely isolated from each other. Mounting installation the aperture in the control panel for. The measuring range of the chlorine sensor must correspond to the adjusted measuring. No operator serviceable parts, service by authorized service personnel only. Product catalogue all innovations presented in detail. Clt10 sc total chlorine analyzer with sc200 controller and. In order to give you a better service prominent uses cookies.
View and download prominent dulcometer d1cb assembly and operating instructions manual online. The certified output guarantees efficient chlorine dioxide production. New measuring, control and sensor technology products 1. Dulcometer controllers prominent fluid controls, inc. Measuring, control and sensor technology 2019 prominent. Trained user a trained user is a person who fulfils the requirements made of an instructed person and who has also received additional training specific to the system from prominent or another.
View and download prominent dulcometer d1ca operating instructions manual online. Residual chlorine analyzer hydroact the hydroact reagentless chlorine analyzer takes online disinfection monitoring to a new level of reliability by offering industryleading performance, an excellent track record of epa method 334. Free chlorine analysis systems fcas provide turnkey panelmounted solutions for free chlorine measurement. The rosemount analytical fcl free chlorine system is intended for the determination of free chlorine in fresh water. Adjustment and operation, measured variable chlorine pr o minent d1c2cl001gb part no. Reagents are intended for chemical analysis and access to them by. Failure to follow this information could lead to harm to the instrument or user. View and download prominent dulcometer d2c operating instructions manual online.
1659 1096 808 1276 225 931 854 1376 281 671 808 1623 845 337 149 1148 1538 1567 864 1478 350 729 60 242 1592 284 96 841 814 130 541 1535 1200 465 525 751 1154 1188 83 1470 705 134 1181 821 215 165 1175